-40%
Apera EC9500 Research-grade Conductivity/TDS/salinity/resistivity Benchtop Meter
$ 450.93
- Description
- Size Guide
Description
30 years of expertise in water analysis instruments and sensorsBUY NOW!
Apera Instruments EC9500 Research-Grade Benchtop Conductivity/TDS/Salinity/Resistivity Meter Kit with Comprehensive GLP Data Management and Data Output to Printer/PC
Apera
EC9500 Research-grade Benchtop Conductivity Meter Kit
Apera EC9500 is a research-grade benchtop conductivity meter that is designed for laboratory professionals, offering long-term reliability in high-accuracy conductivity/TDS/salinity/resistivity measurement.
The meter is rich in features including comprehensive GLP data logging, data export to printer or PC, calibration password protection, buffer organizers, self-diagnosis, i-Guidance, and many more while retaining simplicity in use.
Instrument Features
An advanced yet intuitive user interface with plain language and graphic screen prompts that does not require tedious manual reading or training to operate. Multi-language supports English, German, Spanish, and Chinese.
Manual/Auto. data logger with 1000 groups of storage with comprehensive GLP data input including electrode ID, user ID, sample ID, company name, and calibration password for data protection. USB Data export to PC for further analysis or to a pin-type mini printer for instant report (sold separately).
i-Guide is always available through the “i” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.
Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent magnetic stirrer, and buffer organizers altogether, streamlining the process of measurement and calibration.
Conductivity Measurement
The 2401T-F glass-body conductivity/temp. Electrode allows you to take highly accurate conductivity measurement in any sample solutions within a range of 0 to 200mS/cm at ±1% F.S accuracy.
1 to 4 points automatic calibration with a choice of 4 conductivity standards (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) or user-define standards.
One-tap switch from conductivity to TDS, salinity or resistivity.
Three salinity types for your option: general salinity, saltwater salinity, and NaCl.
Standard BNC conductivity connector, compatible with 2310T-F for high range measurement (up to 2000 mS/cm) and DJS-0.1-F for high purity water; RCA connector for a temperature probe, NTC 30KΩ thermistor
What's in the Kit?
PC9500 Meter with TestBench, USB keyboard, 2401T-F conductivity electrode, conductivity standards (1413µS, 12.88mS, 84µS), USB cable, power adapter (output: 9V, input: 120V), PC-Link software flash drive.
Technical Specs
Conductivity
Range
:
0.00 μ/cm to 2000 mS/cm
Resolution
:
0.01/0.1/1μ/cm; 0.01/0.1/1 mS/cm
Accuracy
:
±.5% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Cell Constant
:
0.1/1/10 cm-1
Reference Temp.
:
15 to 30° (adjustable)
Temp. Compensation Coefficient
:
0.00 to 10.00% (adjustable)
Calibration Points
:
1 to 4 points
Standard Series Options
:
Standard, CH, User-Define
TDS
Range
:
0.00 mg/L to 1000 g/L
Resolution
:
0.01/0.1/1mg/L; 0.01/0.1/1 g/L
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
TDS Factor
:
0.40 to 1.00 (adjustable)
Salinity
Range
:
0.00 to 100 ppt
Resolution
:
0.01/0.1 ppt
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Salinity Type
:
Linear / NaCl / Saltwater
Resistivit
y
Range
:
0.00 Ω·m to 100MΩ·m
Resolution
:
0.1/1 Ω·m; 0.01/0.1/1KΩ·m; 0.1 MΩ·m
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Temperature
Range
:
-10.0 to 110.0°; 14.0 to 230°
Resolution
:
0.1°; 0.1/1°
Accuracy
:
±.5°± digit
Fair Pricing
Payment
We accept payment by any of the following methods:
Credit/Debit Card, PayPal, Google Pay
Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner!
Shipping
We offer
FREE shipping
on all orders!
Your order will dispatched within 1 working day of receiving payment (Monday-Friday).
In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement.
Return
If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not.
You can return a product for up to 30 days from the date you purchased it.
Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt.
Apera EC9500 Research-grade Benchtop Conductivity Meter Kit ---Apera EC9500 is a research-grade benchtop conductivity meter that is designed for laboratory professionals, offering long-term reliability in high-accuracy conductivity/TDS/salinity/resistivity measurement. ---The meter is rich in features including comprehensive GLP data logging, data export to printer or PC, calibration password protection, buffer organizers, self-diagnosis, i-Guidance, and many more while retaining simplicity in use. Instrument Features ---An advanced yet intuitive user interface with plain language and graphic screen prompts that does not require tedious manual reading or training to operate. Multi-language supports English, German, Spanish, and Chinese. ---Manual/Auto. data logger with 1000 groups of storage with comprehensive GLP data input including electrode ID, user ID, sample ID, company name, and calibration password for data protection. USB Data export to PC for further analysis or to a pin-type mini printer for instant report (sold separately). ---i-Guide is always available through the “i” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. ---Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent magnetic stirrer, and buffer organizers altogether, streamlining the process of measurement and calibration. Conductivity Measurement ---The 2401T-F glass-body conductivity/temp. Electrode allows you to take highly accurate conductivity measurement in any sample solutions within a range of 0 to 200mS/cm at ±1% F.S accuracy. ---1 to 4 points automatic calibration with a choice of 4 conductivity standards (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) or user-define standards. ---One-tap switch from conductivity to TDS, salinity or resistivity. ---Three salinity types for your option: general salinity, saltwater salinity, and NaCl. ---Standard BNC conductivity connector, compatible with 2310T-F for high range measurement (up to 2000 mS/cm) and DJS-0.1-F for high purity water; RCA connector for a temperature probe, NTC 30KΩ thermistor What's in the Kit? PC9500 Meter with TestBench, USB keyboard, 2401T-F conductivity electrode, conductivity standards (1413µS, 12.88mS, 84µS), USB cable, power adapter (output: 9V, input: 120V), PC-Link software flash drive. Technical Specs ---Conductivity Range: 0.00 μ/cm to 2000 mS/cm ------Resolution: 0.01/0.1/1μ/cm; 0.01/0.1/1 mS/cm ------Accuracy: ±.5% F.S ± digit ---Temp. Compensation Range: 0 to 50° (auto. or manual) ---Cell Constant: 0.1/1/10 cm-1 ---Reference Temp.: 15 to 30° (adjustable) ---Temp. Compensation Coefficient: 0.00 to 10.00% (adjustable) ---Calibration Points: 1 to 4 points ---Standard Series Options: Standard, CH, User-Define ---TDS Range: 0.00 mg/L to 1000 g/L ------Resolution: 0.01/0.1/1mg/L; 0.01/0.1/1 g/L ------Accuracy: ±.0% F.S ± digit ---Temp. Compensation Range: 0 to 50° (auto. or manual) ---TDS Factor: 0.40 to 1.00 (adjustable) ---Salinity Range: 0.00 to 100 ppt ------Resolution: 0.01/0.1 ppt ------Accuracy: ±.0% F.S ± digit ---Temp. Compensation Range: 0 to 50° (auto. or manual) ---Salinity Type: Linear / NaCl / Saltwater ---Resistivity Range: 0.00 Ω·m to 100MΩ·m ------Resolution: 0.1/1 Ω·m; 0.01/0.1/1KΩ·m; 0.1 MΩ·m ------Accuracy: ±.0% F.S ± digit ---Temp. Compensation Range: 0 to 50° (auto. or manual) ---Temperature Range: -10.0 to 110.0°; 14.0 to 230° ------Resolution: 0.1°; 0.1/1° ------Accuracy: ±.5°± digit
Apera Instruments EC9500 Research-Grade Benchtop Conductivity/TDS/Salinity/Resistivity Meter Kit with Comprehensive GLP Data Management and Data Output to Printer/PC
Apera
EC9500 Research-grade Benchtop Conductivity Meter Kit
Apera EC9500 is a research-grade benchtop conductivity meter that is designed for laboratory professionals, offering long-term reliability in high-accuracy conductivity/TDS/salinity/resistivity measurement.
The meter is rich in features including comprehensive GLP data logging, data export to printer or PC, calibration password protection, buffer organizers, self-diagnosis, i-Guidance, and many more while retaining simplicity in use.
Instrument Features
An advanced yet intuitive user interface with plain language and graphic screen prompts that does not require tedious manual reading or training to operate. Multi-language supports English, German, Spanish, and Chinese.
Manual/Auto. data logger with 1000 groups of storage with comprehensive GLP data input including electrode ID, user ID, sample ID, company name, and calibration password for data protection. USB Data export to PC for further analysis or to a pin-type mini printer for instant report (sold separately).
i-Guide is always available through the “i” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.
Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent magnetic stirrer, and buffer organizers altogether, streamlining the process of measurement and calibration.
Conductivity Measurement
The 2401T-F glass-body conductivity/temp. Electrode allows you to take highly accurate conductivity measurement in any sample solutions within a range of 0 to 200mS/cm at ±1% F.S accuracy.
1 to 4 points automatic calibration with a choice of 4 conductivity standards (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) or user-define standards.
One-tap switch from conductivity to TDS, salinity or resistivity.
Three salinity types for your option: general salinity, saltwater salinity, and NaCl.
Standard BNC conductivity connector, compatible with 2310T-F for high range measurement (up to 2000 mS/cm) and DJS-0.1-F for high purity water; RCA connector for a temperature probe, NTC 30KΩ thermistor
What's in the Kit?
PC9500 Meter with TestBench, USB keyboard, 2401T-F conductivity electrode, conductivity standards (1413µS, 12.88mS, 84µS), USB cable, power adapter (output: 9V, input: 120V), PC-Link software flash drive.
Technical Specs
Conductivity
Range
:
0.00 μ/cm to 2000 mS/cm
Resolution
:
0.01/0.1/1μ/cm; 0.01/0.1/1 mS/cm
Accuracy
:
±.5% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Cell Constant
:
0.1/1/10 cm-1
Reference Temp.
:
15 to 30° (adjustable)
Temp. Compensation Coefficient
:
0.00 to 10.00% (adjustable)
Calibration Points
:
1 to 4 points
Standard Series Options
:
Standard, CH, User-Define
TDS
Range
:
0.00 mg/L to 1000 g/L
Resolution
:
0.01/0.1/1mg/L; 0.01/0.1/1 g/L
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
TDS Factor
:
0.40 to 1.00 (adjustable)
Salinity
Range
:
0.00 to 100 ppt
Resolution
:
0.01/0.1 ppt
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Salinity Type
:
Linear / NaCl / Saltwater
Resistivit
y
Range
:
0.00 Ω·m to 100MΩ·m
Resolution
:
0.1/1 Ω·m; 0.01/0.1/1KΩ·m; 0.1 MΩ·m
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Temperature
Range
:
-10.0 to 110.0°; 14.0 to 230°
Resolution
:
0.1°; 0.1/1°
Accuracy
:
±.5°± digit
BUY NOW!
30 years of expertise in water analysis instruments and sensors
We accept payment by any of the following methods:
Credit/Debit Card, PayPal, Google Pay
Please pay as soon as possible after winning an auction, as that will allow us to post your item to you sooner!
We offer
FREE shipping
on all orders!
Your order will dispatched within 1 working day of receiving payment (Monday-Friday).
In the very unlikely event that your item is lost or damaged during post, then WE are responsible and will issue either a full refund or replacement.
Return
Payment
Shipping
If you are not 100% satisfied with your purchase, you can return the product and get a full refund or exchange the product for another one, be it similar or not.
You can return a product for up to 30 days from the date you purchased it.
Any product you return must be in the same condition you received it and in the original packaging. Please keep the receipt.
Apera
EC9500 Research-grade Benchtop Conductivity Meter Kit
Apera EC9500 is a research-grade benchtop conductivity meter that is designed for laboratory professionals, offering long-term reliability in high-accuracy conductivity/TDS/salinity/resistivity measurement.
The meter is rich in features including comprehensive GLP data logging, data export to printer or PC, calibration password protection, buffer organizers, self-diagnosis, i-Guidance, and many more while retaining simplicity in use.
Instrument Features
An advanced yet intuitive user interface with plain language and graphic screen prompts that does not require tedious manual reading or training to operate. Multi-language supports English, German, Spanish, and Chinese.
Manual/Auto. data logger with 1000 groups of storage with comprehensive GLP data input including electrode ID, user ID, sample ID, company name, and calibration password for data protection. USB Data export to PC for further analysis or to a pin-type mini printer for instant report (sold separately).
i-Guide is always available through the “i” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.
Comes with Apera TestBench that incorporates a flexible electrode holder, an intelligent magnetic stirrer, and buffer organizers altogether, streamlining the process of measurement and calibration.
Conductivity Measurement
The 2401T-F glass-body conductivity/temp. Electrode allows you to take highly accurate conductivity measurement in any sample solutions within a range of 0 to 200mS/cm at ±1% F.S accuracy.
1 to 4 points automatic calibration with a choice of 4 conductivity standards (84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm) or user-define standards.
One-tap switch from conductivity to TDS, salinity or resistivity.
Three salinity types for your option: general salinity, saltwater salinity, and NaCl.
Standard BNC conductivity connector, compatible with 2310T-F for high range measurement (up to 2000 mS/cm) and DJS-0.1-F for high purity water; RCA connector for a temperature probe, NTC 30KΩ thermistor
What's in the Kit?
PC9500 Meter with TestBench, USB keyboard, 2401T-F conductivity electrode, conductivity standards (1413µS, 12.88mS, 84µS), USB cable, power adapter (output: 9V, input: 120V), PC-Link software flash drive.
Technical Specs
Conductivity
Range
:
0.00 μ/cm to 2000 mS/cm
Resolution
:
0.01/0.1/1μ/cm; 0.01/0.1/1 mS/cm
Accuracy
:
±.5% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Cell Constant
:
0.1/1/10 cm-1
Reference Temp.
:
15 to 30° (adjustable)
Temp. Compensation Coefficient
:
0.00 to 10.00% (adjustable)
Calibration Points
:
1 to 4 points
Standard Series Options
:
Standard, CH, User-Define
TDS
Range
:
0.00 mg/L to 1000 g/L
Resolution
:
0.01/0.1/1mg/L; 0.01/0.1/1 g/L
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
TDS Factor
:
0.40 to 1.00 (adjustable)
Salinity
Range
:
0.00 to 100 ppt
Resolution
:
0.01/0.1 ppt
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Salinity Type
:
Linear / NaCl / Saltwater
Resistivit
y
Range
:
0.00 Ω·m to 100MΩ·m
Resolution
:
0.1/1 Ω·m; 0.01/0.1/1KΩ·m; 0.1 MΩ·m
Accuracy
:
±.0% F.S ± digit
Temp. Compensation Range
:
0 to 50° (auto. or manual)
Temperature
Range
:
-10.0 to 110.0°; 14.0 to 230°
Resolution
:
0.1°; 0.1/1°
Accuracy
:
±.5°± digit